The TECRES SPACER G / VANCOGENX® SPACER HIP is designed for partial weight bearing, having a load bearing structure in stainless steel coated with antibiotic bone cement [4] and offering a prolonged antibiotic elution profile [2,3].
The TECRES SPACER G / VANCOGENX SPACER HIP preformed antibiotic loaded spacer is available with either gentamicin or the synergistic [1] combination of gentamicin and vancomycin.
Benefits:
- Ready to use device
- Maintenance of joint space and mobilisation
- Efective in situ release of antibiotic
- Deambulation with partial weight-bearing
- Facilitation of definitive re-implant surgery
- Standardized mechanical performance
- Reduction of functional recovery time after the two stage procedure
Sizes:
- Spacer-G: loaded with Gentamicin (3 sizes of head with long stem and 3 sizes of head with short stem)
- Spacer-G Flat Stem: loaded with Gentamicin with flat stem designed to preserve the greater trochanter (3 sizes of head with long stem and 3 sizes of head with short stem)
- Vancogenx-Spacer: preformed spacer loaded with Vancomycin + Gentamicin (3 sizes of head with long stem and 3 sizes of head with short stem)
- Vancogenx-Spacer Flat Stem: loaded with Vancomycin + Gentamicin with flat stem designed to preserve the greater trochanter (3 sizes of head with long stem and 3 sizes of head with short stem)
References:
[1] Bertazzoni Minelli E, Della Bora T, Benini A. Different microbial biofilm formation on polymethylmethacrylate (PMMA) bone cement loaded with gentamicin and vancomycin. Anaerobe. 2011 Dec;17(6):380-3. doi: 10.1016/j.anaerobe.2011.03.013. Epub 2011 Apr 16.
[2] Bertazzoni Minelli E, Benini A, Magnan B, Bartolozzi P. Release of gentamicin and vancomycin from temporary human hip spacers in two-stage revision of infected arthroplasty. J Antimicrob Chemother. 2004 Feb;53(2):329-34. Epub 2003 Dec 19.
[3] Bertazzoni Minelli E, Benini A, Samaila E, Bondi M, Magnan B. Antimicrobial activity of gentamicin and vancomycin combination in joint fluids after antibiotic-loaded cement spacer implantation in two-stage revision surgery. J Chemother. 2014 Jan 20:1973947813Y0000000157.
[4] Logoluso, N & Champlon, C & Melegati, G & Dell’Oro, F & Romano, C. Gait analysis in patients with a preformed articulated knee spacer. The Knee. 2011 May;19(4): 370-2. doi: 10.1016/j.knee.2011.04.002.
VANCOGENX is a registered trademark of Tecres SpA
Contact us for more information as some products may have selected regional availability
Related products
All productssafeConnect
safeConnect® Safe impact on taper junctions A wide range of impaction forces can be applied when using a conventional mallet. safeConnect delivers a consistent high impact force reducing the chance of micromotion and associated fretting and taper corrosion. Functional principle The instrument is placed on the ball head or cup inlay and is manually pushed … Continued
Read moreRevisioLine
RevisioLine – Universal Blade system for arthroplasty The blade set has been specially developed for the revision of cementless and cemented prostheses. The set consists of ten straight, flexible, ground faced blades. Flexible, curved chisel blades for knee revisions. Hardened-stainless-steel-handle with quick coupling function enables chisel blades to be changed quickly and easily without additional … Continued
Read moreStemExtractor
StemExtractor – Hip stem extractor Universal extraction tool for the removal of femoral prosthesis Advantages Technical specifications
Read more